{"id":17927,"date":"2023-06-27T12:15:44","date_gmt":"2023-06-27T07:15:44","guid":{"rendered":"https:\/\/swanston.uz\/shop\/uncategorized\/medical-gas-central-stations-mgcs\/"},"modified":"2023-07-05T13:51:46","modified_gmt":"2023-07-05T08:51:46","slug":"medical-gas-central-stations-mgcs","status":"publish","type":"product","link":"https:\/\/swanston.uz\/en\/shop\/medical-gas-systems\/medical-gas-central-stations-mgcs\/","title":{"rendered":"Medical Gas Central Stations (MGCS)"},"content":{"rendered":"<div id=\"icj8of2bz_0\" class=\"content content--u-icj8of2bz\" data-do-content=\"{&quot;screen&quot;:{&quot;image&quot;:true,&quot;gallery&quot;:false,&quot;text&quot;:true,&quot;headers&quot;:true}}\">\n<div class=\"localaboutus\">\n<div class=\"localpic localaboutus__pic localpic--smallmore localaboutus__pic--right\"><strong style=\"color: #1b1919; font-size: 22px;\">Cylinder decompression unit<\/strong><\/div>\n<div class=\"localtext\">\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-medium wp-image-16450 alignright\" src=\"https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/frame-19-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/frame-19-300x300.jpg 300w, https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/frame-19-800x800.jpg 800w, https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/frame-19-150x150.jpg 150w, https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/frame-19-768x768.jpg 768w, https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/frame-19-860x860.jpg 860w, https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/frame-19-430x430.jpg 430w, https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/frame-19-700x700.jpg 700w, https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/frame-19.jpg 1000w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>Cylinder decompression devices are designed to supply medical gases (oxygen-nitrous oxide-air-nitrogen-carbon dioxide) to any type of medical gas network where supply continuity is essential and where the pipeline is supplied from high pressure manifold gas cylinders. They comply with all applicable safety codes and regulations and are designed and tested to ensure safe operation. G.SAMARAS SA offers a wide range of decompression units with the following options:<\/p>\n<ul>\n<li>Capacity (75 &#8211; 180 m3\/h)<\/li>\n<li>Outlet pressure (8 or 4 bar)<\/li>\n<li>Operation (pneumatic \/ electric \/ manual)<\/li>\n<\/ul>\n<p>Our company also has parts of a complete decompression block:<\/p>\n<ul>\n<li>Manifolds &#8211; cylinder ramps (2 &#8211; 6 positions)<\/li>\n<li>High pressure evacuation valves<\/li>\n<li>Cylinder holders (1 &#8211; 5 positions)<\/li>\n<li>High pressure pipes (they connect manifold to manifold or manifold to central unit)<\/li>\n<li>Pigtails (they connect the cylinders to the manifold) (connections available: NF, BS, CGA, DIN, UNI)<\/li>\n<\/ul>\n<hr \/>\n<h3><strong>Gas cylinders<\/strong><\/h3>\n<p>G.SAMARAS SA offers high quality gas cylinders for medical or industrial applications. They cover a wide power range while they are made from either 34CrMo4 or aluminium.<\/p>\n<hr \/>\n<h3><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-16062 alignright\" src=\"https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/2-4.jpeg\" alt=\"\" width=\"160\" height=\"160\" srcset=\"https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/2-4.jpeg 160w, https:\/\/swanston.uz\/wp-content\/uploads\/2023\/06\/2-4-150x150.jpeg 150w\" sizes=\"(max-width: 160px) 100vw, 160px\" \/><strong>Cylinder valve<\/strong><\/h3>\n<p>Screw valves for any type of gas (oxygen, nitrogen, helium, argon, mixture, CO2) of various types:<br \/>\n\u2022 Brass<br \/>\n\u2022 Chromium-plated<br \/>\n\u2022 Normal valves<br \/>\n\u2022\u00a0Residual pressure valves<br \/>\n\u2022 Valves with 17E inlet<br \/>\n\u2022 Valves with 25E inlet<br \/>\n\u2022 Valves with inlet M 25&#215;2<br \/>\n\u2022 Valves with inlet M 18&#215;1.5<br \/>\n\u2022 Valves with working pressure 200 bar<br \/>\n\u2022 Valves with working pressure 300 bar<\/p>\n<\/div>\n<div class=\"clear\"><\/div>\n<div class=\"localaboutus__price-title\"><\/div>\n<div class=\"localaboutus__price\"><\/div>\n<div class=\"localpics\"><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Cylinder decompression unit Cylinder decompression devices are designed to supply medical gases (oxygen-nitrous oxide-air-nitrogen-carbon dioxide) to any type of medical<\/p>\n","protected":false},"featured_media":17590,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[88],"product_tag":[],"_links":{"self":[{"href":"https:\/\/swanston.uz\/en\/wp-json\/wp\/v2\/product\/17927"}],"collection":[{"href":"https:\/\/swanston.uz\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/swanston.uz\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/swanston.uz\/en\/wp-json\/wp\/v2\/comments?post=17927"}],"version-history":[{"count":0,"href":"https:\/\/swanston.uz\/en\/wp-json\/wp\/v2\/product\/17927\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/swanston.uz\/en\/wp-json\/wp\/v2\/media\/17590"}],"wp:attachment":[{"href":"https:\/\/swanston.uz\/en\/wp-json\/wp\/v2\/media?parent=17927"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/swanston.uz\/en\/wp-json\/wp\/v2\/product_cat?post=17927"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/swanston.uz\/en\/wp-json\/wp\/v2\/product_tag?post=17927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}